Your Systems Don't Speak
the Same Language
N2, PUP, LON, Modbus, BACnet — building automation is a Tower of Babel. We're the translators that make your systems work together.
Discuss Protocol IntegrationThe Protocol Problem
Every BMS manufacturer developed their own communication protocol. For decades, this kept you locked into their ecosystem. Today, it's a barrier to modernization, integration, and data access.
Vendor Lock-in
Proprietary protocols mean you can only use that vendor's equipment and services.
Integration Barriers
Can't connect to analytics platforms, energy management, or other building systems.
Obsolescence Risk
Legacy protocols have shrinking support. The expertise to maintain them is disappearing.
Protocols We Integrate
From legacy proprietary buses to modern open standards — we speak them all.
BACnet
Open Standard
The industry standard for building automation. MS/TP, IP, and Ethernet variants. Where legacy systems need to go.
Learn about BACnet integration →
N2 Bus
Johnson Controls
JCI's legacy field bus protocol. Connects DX-9100, VMA, TEC controllers. Migration to BACnet is critical.
Learn about N2 integration →
LonWorks
Open (Echelon)
Peer-to-peer network protocol. Common in '90s-'00s installations. Still functional but declining support.
Learn about LON integration →
Modbus
Industrial Standard
Simple, reliable protocol for equipment integration. RTU (serial) and TCP (Ethernet) variants.
Learn about Modbus integration →
PUP Protocol
American Auto-Matrix
AAM's Public Unitary Protocol. Connects SOLO controllers. Critical for AAM migrations.
See AAM services →Other Protocols
Proprietary
CCN, Comm5, P1/P2, C-Bus, and other vendor-specific protocols. We've seen them all.
Ask about your protocol →How We Bridge Protocols
Protocol integration isn't just about hardware gateways. It requires understanding both sides — the legacy system's data model and the target system's requirements.
Discovery
Map the existing network — devices, points, addresses, relationships.
Translation
Configure protocol drivers or gateways to expose legacy points.
Normalization
Standardize naming, units, and data formats for the target system.
Verification
Test bidirectional communication, command execution, and data integrity.
Integration Tools
We use the right tool for each integration challenge:
- → Niagara Framework
Extensive driver library for legacy protocols
- → Protocol Gateways
Hardware bridges for serial protocols
- → BACnet Routers
Expose legacy as BACnet objects
- → Custom Development
When off-the-shelf doesn't exist
Common Integration Scenarios
Unified Building Dashboard
Multiple BMS platforms from different eras need to report to a single interface. We integrate them all into Niagara or another supervisor.
Protocols: Any → Niagara/BACnet
Energy Analytics Platform
Your analytics platform needs BACnet or API data, but your BMS speaks N2 or LON. We expose the data in the format they need.
Protocols: Legacy → BACnet/IP or API
New Equipment Integration
New chiller or AHU has BACnet, but your existing BMS only speaks a legacy protocol. We bridge the gap without replacing everything.
Protocols: BACnet ↔ Legacy
Phased Migration
Upgrading in stages — new BACnet controllers alongside legacy devices. We keep everything talking during the transition.
Protocols: Mixed environment
What Protocol Are You Stuck With?
Tell us what you have and where you need to go. We'll figure out the translation.
Discuss Your Integration